Hi Gurus,
I've looked at both these threads which discusses this error message but they are not relevant to my situation.
https://scn.sap.com/thread/1385855
https://scn.sap.com/thread/1890170
I've a storage type with no putaway strategy "manual stock placement". I've defined strategies for both storage type and storage section and updated the material master accordingly. There is also plenty of storage bins against the storage type/section.
However, when I try to putaway stock (LT06), I get the error message L3009. If I put the bin, the error goes away, but I don't think there should be an error message to begin with because I'm using "manual stock placement".
Have you faced the same issue for storage types with "manual stock placement"?
Thank you.